DIN Rail Mounted Relay Range, 250VAC, learn enabled |
|
|
| |
|

|
12 Channel Relay with C-Bus Power Supply L5512RVF
12 Channel Voltage Free Relay, DIN Rail Mounted
Learn Enabled, DIN rail mounted relay unit featuring 12 channels of voltage free relay switching. 12M modules wide. Rated at 10A incandescent or 10A fluorescent load per channel. Incorporates a 200mA C-Bus Power Supply, a software selectable Network Burden and C-Bus System Clock.
A maximum of 10 units may be connected to any C-Bus Network. |

|
12 Channel Relay L5512RVFP
12 Channel Voltage Free Relay, DIN Rail Mounted
Learn Enabled, DIN rail mounted relay unit featuring 12 channels of voltage free relay switching. 12M modules wide. Rated at 10A incandescent or 10A fluorescent load per channel. Incorporates a software selectable Network Burden and C-Bus System Clock.
A maximum of 100 units may be connected to any C-Bus Network. These units draw 18mA from C-Bus when mains is not connected. They do not source current to the network with mains connected. |

|
8 Channel Relay with C-Bus Power Supply L5508RVF
8 Channel Voltage Free Relay, DIN Rail Mounted
Learn Enabled, DIN rail mounted relay unit featuring 8 channels of voltage free relay switching. 12M modules wide. Rated at 10A incandescent or 10A fluorescent load per channel. Incorporates a 200mA C-Bus Power Supply, a software selectable Network Burden and C-Bus System Clock.
A maximum of 10 units may be connected to any C-Bus Network. |

|
8 Channel Relay L5508RVFP
8 Channel Voltage Free Relay, DIN Rail Mounted
Learn Enabled, DIN rail mounted relay unit featuring 8 channels of voltage free relay switching. 12M modules wide. Rated at 10A incandescent or 10A fluorescent load per channel. Incorporates a software selectable Network Burden and C-Bus System Clock.
A maximum of 100 units may be connected to any C-Bus Network. These units draw 18mA from C-Bus when mains is not connected. They do not source current to the network with mains connected. |

|
4 Channel Relay with C-Bus Power Supply L5504RVF
4 Channel Voltage Free Relay, DIN Rail Mounted
Learn Enabled, DIN rail mounted relay unit featuring 4 channels of voltage free relay switching. 8M modules wide. Rated at 10A incandescent or 10A fluorescent load per channel. Incorporates a 200mA C-Bus Power Supply, a software selectable Network Burden and C-Bus System Clock.
A maximum of 10 units may be connected to any C-Bus Network. |

|
4 Channel Relay L5504RVFP
4 Channel Voltage Free Relay, DIN Rail Mounted
Learn Enabled, DIN rail mounted relay unit featuring 4 channels of voltage free relay switching. 8M modules wide. Rated at 10A incandescent or 10A fluorescent load per channel. Incorporates a software selectable Network Burden and C-Bus System Clock.
A maximum of 100 units may be connected to any C-Bus Network. These units draw 18mA from C-Bus when mains is not connected. They do not source current to the network with mains connected. |

|
Changeover Relay with Power Supply L5504RVFC
4 Channel Changeover Relay, DIN Rail Mounted
A DIN rail mounted, 4-channel changeover relay unit, 8M wide. Common, Normally Open and Normally Closed terminals are provided for each relay. The contacts on each relay can be wired by the installer to provide interlocking features for control of air-conditioning systems (on / off, medium and high) and shutter or blind control (up / down). Each relay is rated at 10A resistive, 5A incandescent/inductive, 1A fluorescent.
This Unit also incorporates a 200mA C-Bus Power Supply |

|
Changeover Relay L5504RVFCP
4 Channel Changeover Relay, DIN Rail Mounted
A DIN rail mounted, 4-channel changeover relay unit, 8M wide. Common, Normally Open and Normally Closed terminals are provided for each relay. The contacts on each relay can be wired by the installer to provide interlocking features for control of air-conditioning systems (on / off, medium and high) and shutter or blind control (up / down). Each relay is rated at 10A resistive, 5A incandescent/inductive, 1A fluorescent. |

|
4 Channel 20A Relay with C-Bus P/Supp L5504RVF20
4 Channel 20A Voltage Free Relay, DIN Rail Mounted
Learn Enabled, DIN rail mounted relay unit featuring 4 channels of voltage free relay switching. 12M modules wide. Rated at 20A incandescent, 20A HID or 20A fluorescent load per channel. Incorporates a 200mA C-Bus Power Supply, a software selectable Network Burden and C-Bus System Clock.
Each relay channel features magnetic latching and a built in mechanical level for manual changeover of relay state.
A maximum of 10 units may be connected to any C-Bus Network. |

|
4 Channel, 20A Relay L5504RVF20P
4 Channel 20A Voltage Free Relay, DIN Rail Mounted
Learn Enabled, DIN rail mounted relay units featuring 4 channels of voltage free relay switching. 12M modules wide. Rated at 20A incandescent, 20A HID or 20A fluorescent load per channel. Incorporates a software selectable Network Burden and C-Bus System Clock.
These units draw 18mA from the C-Bus when mains is not connected. They do not source current to the network with mains connected.
Each relay channel features magnetic latching and a built in mechanical level for manual changeover of relay state.
A maximum of 100 units may be connected to any C-Bus Network. |

|
Latching Relay Driver 5504RDP
4 Channel Relay Driver, 250VAC
DIN rail mounted Relay Driver unit featuring 4 channels capable of driving the coils of up to four external 20A relays (one per channel). Note this Relay Driver does not directly control a mains output load and must be used with Cat Numbers 5000RL20 or 5002RL20.
Incorporates a software selectable Network Burden and C-Bus System Clock. A maximum of 100 units may be connected to any C-Bus Network.
These units draw 18mA from the C-Bus when mains is not connected. They do not source current to the network with mains connected. Does not included lean enabled features. |

|
Latching Relay Driver with 200mA C-Bus P/Supp L5504RD
4 Channel Relay Driver 250VAC, DIN Rail Mounted
Learn Enabled, DIN rail mounted Relay Driver unit featuring 4 channels capable of driving the coils of up to four external 20A relays (one per channel).
Note this Relay Driver does not directly control a mains output load and must be used in conjunction with Cat Numbers 5000RL20 or 5002RL20.
Incorporates a 200mA C-Bus Power Supply, a software selectable Network Burden and C-Bus System Clock. A maximum of 10 units may be connected to any C-Bus Network. |

|
L5501RBCP
C-Bus Motorised Blinds/Curtains/Shutter Relay
250V AC
No C-Bus Power Supply |

|
Wall Mounting Enclosure 5501RE
Enclosure to suit Blind/Curtain/Shutter Relay
|

|
Single, Heavy Duty Relay 5000RL20
Single relay 250VAC, 20A inductive load
Single, heavy duty, 20A DIN rail mounted, mechanically latched relay. Suitable for incandescent, HID and fluorescent loads.
Incorporates an auxiliary output contact and a mechanical on/off override for manual operation.
Must be used in conjunction with the Cat Numbers 5504RDP, L5504RD or L5504RDP Relay Driver products. |

|
Dual, 20A Magnetically Latched Relay 5002RL20
Dual Relay 250VAC, 20A Inductive Load
Dual, DIN rail mounted, 20A magnetically latching relay unit, must be used in conjunction with the C-Bus 5504RDP, L5504RD or L5504RDP Relay Driver products.
Compatible with 20A incandescent, inductive or fluorescent loads. DIN Rail mounted, 4M wide.
Incorporates mechanical overrides accessible by the user. The mechanical lever is labelled with ON and OFF to indicate
relay status. |

|
1 Channel Relay 5101R
1 Channel Relay 250VAC, 10A Inductive Load
Suitable for incandescent, inductive and fluorescent switching up to the rated maximum load of 10A per channel. The relay does not draw any current from C-Bus when mains power is connected.
Note: Does not include learn enabled features. |

|
1 Channel Relay with Mains and C-Bus Cable 5101RC
1 Channel Relay 250VAC, 10A Inductive Load
Unit comes complete with 3 pin mains, flex and plug and C-Bus lead with preterminated RJ45 connector. |

|
2 Channel Relay 5102RVF
2 Channel Voltage Free Relay 250VAC
Two Channel Relay Unit suitable for incandescent, inductive and fluorescent switching up to the rated maximum load of 10A per channel. The relas does not draw any current from C-Bus when mains power is connected.
Note:Does not include learn enabled features. |
|
|
|
|